Facade lighting scheme



Dear Reader,



This is one of my façade lighting project. The building is an IT office with edgy design thus the feature can be highlighted by simply highlighting the edges.









Waiting for the project to be get completed. Will share the pics when its completed :) .


Sunday, January 27, 2019

What is Color Rendering Index (CRI)?

Color Rendering Index (CRI) 

Lets break it down first 
Color : We all know what that 'color' means.
Rendering : "process (an outline image) using colour and shading in order to make it appear solid and three-dimensional" - Google definition.
Index : "a sign or measure of something" - Google definition.

In lighting linguistics, CRI translates as the ability of the light source to bring out the colours of the object when the light falls on it. This parameter is measured in reference to rendering of the colors under the effect of the natural lights or under the sunlight.

Interpretation of CRI values:
CRI 90 - The colors will be as good as 90% when placed under sunlight. - (good)
CRI 85 - The colors will be as good as 85% when placed under sunlight. - (average)
CRI 70 - The colors will be as good as 70% when placed under sunlight. - (poor)
The higher the CRI, the better.

CRI is a crucial when it comes to indoor lighting. It really enhances the overall appearance of area or that particular painting which you want to stand out or that expensive carpet on the floor or that table meant for banquets.  

An easy experiment to understand the difference:
Just open the palm of your hand on a broad daylight and pay attention to the blood vessels and the veins. Repeat the same under artificial light of CRI 90 then gradually down to CRI 70. One can see how these minute colors of blood vessel and veins become less & less prominent to the point one really has to look t it with more attention to see the difference. 

So if there is an expensive painting say for example 'Mona Lisa' , with lots of different shades of all the colors known to "man" kind, will certainly look flat and bland. The missing colour details would strip the artwork of its magic and charm. 

Therefore higher the CRI the better. Select the lamps with higher CRI for important indoor  area or for a particular task of highlighting / focussing.

Sunday, December 30, 2018

Back lighting - Coves

Dear Reader,

In this blog we talk about the placement/positioning of the of the light source. Its important to conduct a mock up. Mock up is like a rehearsal before one takes up full scale installation. Its important to note the following:
1) Depth of the niche / cavity -  this gives the idea on how to place the light source and the angle.
2) Texture or the type of surfaces - to know how likely one can see the hotspots / dots on the surface.

Below picture shows the positioning of the profiles / channels on which the led strips (in this case) is to be angled for the best results. However its important to note depending on the surface and the visual impact the decision has to be taken. Sometimes the brightness is the concern, the distance to which the light travels and sometimes just a faint glow is the intent. It all depends on how the finished project is going to look like.




 Its always important to make sure that the surface is smooth so that the undulations of the surface do not impact the appearance of the finished project. In my next blog I'll try to explain the how to obtain the best results from the flexible strip lights.




Monday, November 12, 2018

Classification of Luminaires

Dear Reader,

Todays post is about classification of indoor luminaires. I've tried my best to get them sorted and that's just part 1 of 3 because we have outdoor luminaires and hazardous luminaires are a different breed. So for now let settle with indoors.




Sunday, November 11, 2018

Back lighting

Dear Reader,

Todays topic is about back lighting through perforated sheets. I would be using images from google, which best describe the intended techniques.There are several ways to back light a panel but some of the methods commonly chosen for a residential, hotel or indoor applications, are as follows:

Case 1

Lets focus on the perforated sheet, probably made of metal sheet or an MDF. Notice the bright inner edges. Its because the light source has been installed on the inner side of the assembly and placed on the perimeter. Such arrangements are often customised according to the design or available spaces. So the technique may also vary.

In this case a flexible-cuttable-linear lighting fixture has been chosen, in other words LED Strips (<--google it). These strips are mounted via aluminum, channel flat or in angular shape. Angular shape is preferred but in some cases the light source gets visible which causes glare and kills the effect, so choose carefully.

The other methods could have been:
1) LED modules (google it): which offer wider range output and controls.
2) Linear rigid lighting: for higher outputs, They resemble batten lights.
3) RGB version of LED Strips.


Case 2

This is a case of backlighting on the ceiling. Yes of course LED Strips can be used here. One should really consider a Panel LED Modules(google). These can be considered for ceiling, wall and even floor mount applications. They are basically best known for their uniformity of light effect and the drama that they create. You will need an expert hands for the job here as they are a delicate piece of light source.



Case 3

For outdoor application always use an IP protected lighting products (IP54 onwards). If the  enclosure is housing the light source is an IP protected one then indoor products can also be installed, i.e. IP20 rated lighting products. Conditions of using an IP 20 lighting products for an outdoor application will be discussed separately. Please read about the IP ratings or Ingress protection ratings on wiki or google.


Do's and Don't

1) Light source should and always be invisible from the general visual field.
2) Can go for RGB version. Pay attention to the application and purpose for which the area will be used.
3) LED strips should be installed on aluminum channels which makes the installation and lighitng effect to be in a straight line. It also helps in dissipating the heat from the led strips.
4) Special heat absorbing adhesive can be used for higher wattage led strips.
5) NO DOTS. Yes, dots should not be visible. Its a sudden death. Try to use diffusers or aim / place the source away from the visual field.
6) Don't go crazy with brightness. Brightness is not the answer, if the effect fails to improve the look and feel of the area then its all waste of money and time.


References of pictures used in this blog:
1)
https://www.google.com/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&cad=rja&uact=8&ved=2ahUKEwi2nPnRw8zeAhUN3Y8KHQFiBvQQjRx6BAgBEAU&url=https%3A%2F%2Fwww.indiamart.com%2Fproddetail%2Fdecorative-jali-4157134897.html&psig=AOvVaw3H7vtBSHhMFf8PZy0VZFLk&ust=1542031488199094

2) 
https://i0.wp.com/img03.olx.in/images_olxin/302842995_1_1000x700_down-ceiling-designing-with-lighting-mdf-cutting-amritsar.jpg?resize=480%2C360&amp;ssl=1


Sunday, September 9, 2018

Glossary - Z


Z 

zonal-cavity inter reflectance method a procedure for calculating coefficients of utilization, wall exitance coefficients, and ceiling cavity exitance coefficients, taking into consideration the luminaire intensity distribution, room size and shape (cavity ratio concepts), and room reflectances. It is based on flux transfer theory. 

zonal constant a factor by which the mean intensity emitted by a source of light in a given angular zone is multiplied to obtain the lumens in the zone. See Chapter 2, Measurement of Light and Other Radiant Energy. 

zonal factor interreflection method a procedure used for calculating coefficients of utilization, based on integral equations, that takes into consideration the ultimate disposition of luminous flux from every 10° zone from luminaires. 

zonal factor method a procedure for predetermining, from typical luminaire photometric data in discrete angular zones, the proportion of luminaire output that would be incident initially (without interreflections) on the workplane, ceiling, walls, and floor of a room. 

zonal multipliers multipliers for the flux in each 10-degree conical zone from 0° (nadir) to 90° (horizontal) from a luminaire, expressing the fraction of that zonal flux that is directly incident on the floor of a room cavity. These multipliers are a function of the room cavity ratio and are used to determine the direct ratio.

Glossary - W


W 

watt† the unit of power (rate of doing work). In electrical calculations, one watt is the power produced by a current of one ampere across a potential difference of one volt. The symbol often used in equations is "P," although "W" is also acceptable. 

wavelength† the distance between two successive points of a periodic wave, in the direction of propagation, at which the oscillation has the same phase.

wide-angle diffusion that in which flux is scattered at angles far from the direction that it would take by regular reflection or transmission. See narrow-angle diffusion. 

wide-angle luminaire a luminaire that concentrates the light within the cone of a comparatively large solid angle. See narrow-angle luminaire. 
workplane the plane on which a visual task is usually done, and on which the illuminance is specified and measured. Unless otherwise indicated, this is assumed to be a horizontal plane 0.76 m (30 in.) above the floor.

Glossary - V


V 

vacuum lamp an incandescent lamp in which the filament operates in an evacuated bulb. 

valance a longitudinal shielding member mounted across the top of a window or along a wall (and is usually parallel to the wall) to conceal light sources, giving both upward and downward distributions. 

valance lighting comprising light sources shielded by a panel parallel to the wall at the top of a window. 

vapor-tight luminaire a luminaire designed and approved for installation in damp or wet locations. It also is described as enclosed and gasketed. 

veiling brightness a brightness superimposed on the retinal image that reduces its contrast. It is this veiling effect produced by bright sources or areas in the visual field that results in decreased visual performance and visibility. 

veiling reflection regular reflections that are superimposed upon diffuse reflections from an object that partially or totally obscure the details to be seen by reducing the contrast. This sometimes is called reflected glare. Another kind of veiling reflection occurs when one looks through a plate of glass. A reflected image of a bright element or surface can be seen superimposed on what is viewed through the glass plate. 

visibility the quality or state of being perceivable by the eye. In many outdoor applications, visibility is defined in terms of the distance at which an object can be just perceived by the eye. In indoor applications it usually is defined in terms of the contrast or size of a standard test object, observed under standardized viewing conditions, having the same threshold as the given object. See visibility (meteorological). 

vision† See central (foveal) vision, mesopic vision, peripheral vision, photopic vision, and scotopic vision. 

visual acuity a measure of the ability to distinguish fine details, measured with a set of optotypes (test types for determining visual acuity) of different sizes. Quantitatively, it is the reciprocal of the minimum angular size in minutes of the critical detail of an object that can just be seen. 

visual angle the angle that an object or detail subtends at the point of observation. It usually is measured in minutes of arc. 

visual comfort probability (VCP) the rating of a lighting system expressed as a percent of people who, when viewing from a specified location and in a specified direction, will be expected to find it acceptable in terms of discomfort glare. Visual comfort probability is related to the discomfort glare rating (DGR). 

visual field the locus of objects or points in space that can be perceived when the head and eyes are kept fixed. Separate monocular fields for the two eyes can be specified or the combination of the two. See binocular portion of the visual field, central visual field, monocular visual field, and peripheral visual field. 

visual perception the interpretation of impressions transmitted from the retina to the brain in terms of information about a physical world displayed before the eye.  Note Visual perception involves any one or more of the following recognizing the presence of something (object, aperture, or medium); identifying it; locating it in space; noting its relation to other things; and identifying its movement, color, brightness, or form. 

visual performance the quantitative assessment of the performance of a visual task, taking into consideration speed and accuracy. 

visual range (of a light or object) the maximum distance at which that particular light (or object) can be seen and identified. 

visual task conventionally designates those details and objects that must be seen for the performance of a given activity, and includes the immediate background of the details or objects.  Note The term visual task as used is a misnomer because it refers to the visual display itself and not the task of extracting information from it. The task of extracting information also has to be differentiated from the overall task performed by the observer. 
volt† the difference in electrical potential between two points in a circuit. It is also called the electromotive force. The symbol often used in equations is "E" (from the latter term), although "V" is also acceptable.

Glossary - U


U 

ultraviolet lamp a lamp that emits a significant portion of its radiative power in the ultraviolet (UV) part of the spectrum; the visible radiation is not of principal interest. 

upward component that portion of the luminous flux from a luminaire emitted at angles above the horizontal. See downward component. 

Glossary - T


T 

table lamp a portable luminaire with a short stand, suitable for standing on furniture. 

tail lamp a lighting device used to designate the rear of a vehicle by a warning light. 

task ambient lighting a combination of task lighting and ambient lighting within an area such that the general level of ambient lighting is lower than and complementary to the task lighting. 

task lighting directed to a specific surface or area that provides illumination for visual tasks. 

thermopile† a thermal radiation detector consisting of a number of thermocouples interconnected in order to increase the sensitivity to incident radiant flux. 

torchère an indirect floor lamp that sends all or nearly all of its light upward. 

total internal reflectance (TIR)† total reflection of a light ray at a surface of a transmitting medium occurs when the angle of incidence exceeds a certain value whose sine equals n2/n1, the ratio of indices of refraction, or when sin r = 1, where r equals

transition lighting in roadway lighting, lighting gauged to compensate for visual adaptation between regions of high and low light level, as when entering tunnels. 

translucent† transmitting light diffusely or imperfectly. 

transparent† having the property of transmitting rays of light through its substance so that bodies situated beyond or behind can be distinctly seen (opposed to opaque and usually distinguished from translucent). 
troffer a long recessed lighting unit usually installed with the opening flush with the ceiling. The term is derived from "trough" and "coffer"

Glossary - S


S 

scoop a floodlight consisting of a lamp in an ellipsoidal or paraboloidal matte reflector, usually in a fixed relationship, though some types permit adjustment of the beam shape. 

scotopic vision mediated essentially or exclusively by the rods. It is generally associated with adaptation to a luminance below about 0.034 cd/m2. See photopic vision. 

self-ballasted lamps any arc discharge lamp of which the current-limiting device is an integral part. 

semi-direct lighting involving luminaires that distribute 60 to 90% of the emitted light downward and the balance upward. 

semi-indirect lighting involving luminaires that distribute 60 to 90% of the emitted light upward and the balance downward. 

service period the number of hours per day for which daylighting provides a specified illuminance level. It often is stated as a monthly average. 

set light in theatrical lighting, the separate illumination of background or scenic elements. 

shade a screen made of opaque or diffusing material that is designed to prevent a light source from being directly visible at normal angles of view. 

shielding angle (of a luminaire) the angle between a horizontal line through the light center and the line of sight at which the bare source first becomes visible. See cutoff angle (of a luminaire). 

side light lighting from the side to enhance subject modeling and place the subject in depth, apparently separated from the background. 

signal shutter a device that modulates a beam of light by mechanical means for the purpose of transmitting intelligence. 

sky factor the ratio of the illuminance on a horizontal plane at a given point inside a building due to the light received directly from the sky, to the illuminance due to an unobstructed hemisphere of sky of uniform luminance equal to that of the visible sky. 

sky light† visible radiation from the sun redirected by the atmosphere. 

soft light (1) diffuse illumination that produces soft-edged, poorly defined shadows on the background when an object is placed in its path; (2) a luminaire designed to produce such illumination. 

solar efficacy the ratio of the solar illuminance constant to the solar irradiance constant. The current accepted value is 94.2 lm/W. 

spacing-to-mounting-height ratio, S/MHwp† the ratio of the actual distance between luminaire centers to the mounting height above the workplane. Also, an obsolete term that described a characteristic of interior luminaires. See luminaire spacing criterion. 

special color rendering index, Ri measure of color shift of various standardized special colors, including saturated colors, typical foliage, and Caucasian skin. It also can be defined for other color samples when the spectral reflectance distributions are known. 

specular surface one from which the reflection is predominantly regular. See regular (specular) reflection. 

speed of light† the speed of all radiant energy, including light, is 2.9979258 × 108 m/s in vacuum (approximately 186,000 mi/s). In all material media the speed is less and varies with the material's index of refraction, which itself varies with wavelength. 

sphere illumination illumination on a task from a source providing equal luminance in all directions about that task, such as an illuminated sphere with the task located at the center. 

spotlight any of several different types of luminaires with narrow beam angle designed to illuminate a well-defined area. In motion pictures, generic for Fresnel lens luminaires. Also, a form of floodlight, usually equipped with lenses and reflectors to give a fixed or adjustable narrow beam. 

standard source an electric light source having the same spectral power distribution as a specified standard illuminant. 

starter a device used in conjunction with a ballast for the purpose of starting an electric-discharge lamp. 

state of chromatic adaptation the condition of the chromatic properties of the visual system at a specified moment as a result of exposure to the totality of colors of the visual field currently and in the past. 

stray light (in the eye) light from a source that is scattered onto parts of the retina lying outside the retinal image of the source. 

street lighting luminaire a complete lighting device consisting of a light source and ballast, where appropriate, together with its direct appurtenances such as globe, reflector, refractor, housing, and such support as is integral with the housing. The pole, post, or bracket is not considered part of the luminaire.  Note Modern street lighting luminaires contain the ballasts for high-intensity discharge lamps where such lamps are used; a photocontrol can be mounted on the luminaire. 

street lighting unit the assembly of a pole or lamp post with a bracket and a luminaire. 

striplight (theatrical) once an open trough reflector containing a series of lamps; now usually a compartmentalized luminaire with each compartment containing a lamp, reflector, and color frame holder, wired in rotation in three or four circuits and used as borderlights, footlights, or cyclorama lighting from above or below. Often in short 0.9- to 2.4-m [3- to 8-ft] portable sections. 

stroboscopic lamp (strobe light) a flash tube designed for repetitive flashing. 

supplementary lighting used to provide an additional quantity and quality of illumination that cannot readily be obtained by a general lighting system and that supplements the general lighting level, usually for specific work requirements. 

surface-mounted luminaire a luminaire that is mounted directly on a ceiling. 

suspended (pendant) luminaire a luminaire that is hung from a ceiling by supports. 
Systeme Internationale (SI)† a measurement system used throughout the world, commonly referred to as the metric system. Public Law 100-418 designated the metric system as the preferred system of weights and measures for the United States. 

Glossary - R


R 

radiant energy, Q energy traveling in the form of electromagnetic waves. It is measured in units of energy such as joules or kilowatt hours. See spectral radiant energy. 

radiometry the measurement of quantities associated with radiant energy and power. 

rated lamp life the life value assigned to a particular type lamp. This is commonly a statistically determined estimate of average or of median operational life. For certain lamp types other criteria than failure to light can be used; for example, the life can be based on the average time until the lamp type produces a given fraction of initial luminous flux. 

reflectance of a surface or medium, ρ = Φr/Φi the ratio of the reflected flux to the incident flux. Reflectance is a function of: 

1. Geometry 

a. of the incident flux  b. of collection for the reflected flux 

2. Spectral distribution

a. characteristic of the incident flux  b. weighting function for the collected flux 

3. Polarization 

a. of the incident flux  b. component defined for the collected flux. 

reflectance factor, R the ratio of the flux actually reflected by a sample surface to that which would be reflected into the same reflected-beam geometry by an ideal (glossless), perfectly diffuse (lambertian), completely reflecting standard surface irradiated in exactly the same way as the sample. Note the analogies to reflectance in the fact that nine canonical forms are possible that "spectral" can be applied as a modifier, that it can be luminous or radiant reflectance factor, and so on. Note that reflectance cannot exceed unity, but reflectance factor can have any value from zero to values approaching infinity. 

reflected glare glare resulting from reflections of high luminances in polished or glossy surfaces in the field of view. It usually is associated with reflections from within a visual task or areas in close proximity to the region being viewed. See veiling reflection. 

reflection a general term for the process by which the incident flux leaves a (stationary) surface or medium from the incident side without change in frequency.  Note Reflection is usually a combination of regular and diffuse reflection. See regular (specular) reflection, diffuse reflection, and veiling reflection. 

reflectivity† reflectance of a layer of a material of such a thickness that there is no change of reflectance with increase in thickness. 

reflectometer a photometer for measuring reflectance.  Note Reflectometers can be visual or physical instruments. 

reflector a device used to redirect the flux from a source by the process of reflection. See retro-reflector. 

refraction† the process by which the direction of a ray of light changes as it passes obliquely from one medium to another in which its speed is different. 

refractor a device used to redirect the flux from a source, primarily by the process of refraction. 

retina a membrane lining the posterior part of the inside of the eye. It comprises photoreceptors (cones and rods) that are sensitive to light and nerve cells that transmit to the optic nerve the responses of the receptor elements. 

rhythmic light a light that when observed from a fixed point has a luminous intensity that changes periodically. See equal interval (isophase) light, flashing light, group flashing light, interrupted quickflashing light, and occulting light. 

room cavity the cavity formed by the plane of the luminaires, the work plane, and the wall surfaces between these two planes. 

room cavity ratio (RCR) a number indicating room cavity proportions, calculated from the length, width, and height. See zonal-cavity interreflectance method. 

room utilization factor (utilance) the ratio of the luminous flux (lumens) received on the workplane to that emitted by the luminaire. Note This ratio sometimes is called interflectance. Room utilization factor is based on the flux emitted by a complete luminaire, whereas coefficient of utilization is based on the total flux generated by the lamps in a luminaire. 
room surface dirt depreciation (RSDD) the fractional loss of task illuminance due to dirt on the room surfaces.

Glossary - Q


Q 

quality of lighting pertains to the distribution of luminance in a visual environment. The term is used in a positive sense and implies that all luminances contribute favorably to visual performance, visual comfort, ease of seeing, safety, and aesthetics for the specific visual tasks involved.  

Glossary - P


P 

panel (open) face exit sign† a transilluminated sign where both the exit legend and background are translucent. 

parking lamp a lighting device placed on a vehicle to indicate its presence when parked. 

partial diffusion† See incomplete diffusion. 

partly cloudy sky a sky that has 30 to 70% cloud cover. 

passing beams† See lower (passing) beams. 

pendant luminaire† See suspended (pendant) luminaire. 

perceived light source color the color perceived to belong to a light source. 

perceived object color† the color perceived to belong to an object resulting from characteristics of the object, of the incident light, and of the surround, the viewing direction, and observer adaptation. See object color. 

percent flicker a relative measure of the cyclic variation in output of a light source (percent modulation). It is given by the expression where A is the maximum and B is the minimum output during a single cycle. See Chapter 6, Light Sources. 

perfect diffusion that in which flux is uniformly scattered in accord with Lambert's cosine law. 

peripheral vision the seeing of objects displaced from the primary line of sight and outside the central visual field. 

peripheral visual field that portion of the visual field that falls outside the region corresponding to the foveal portion of the retina. 

phosphor mercury lamp† see mercury-fluorescent lamp. 

phosphorescence the emission of light as the result of the absorption of radiation, and continuing for a noticeable length of time after excitation (longer than approximately 10−8 s). 

phot, ph a unit of illuminance equal to one lumen per square centimeter. The use of this unit is deprecated. 

photobiology a branch of biology that deals with the effects of optical radiation on living systems. 

photometer an instrument for measuring photometric quantities such as luminance, luminous intensity, luminous flux, or illuminance. See densitomer, goniophotometer, illuminance (lux or footcandle) meter, integrating photometer, reflectometer, spectrophotometer, and transmissometer. 

photometry the measurement of quantities associated with light.  Note Photometry can be either visual, in which the eye is used to make a comparison, or physical, in which measurements are made by means of physical receptors. 

phototherapy the treatment of disease involving the use of optical radiation. 

physical photometer an instrument containing a physical receptor and associated filters that is calibrated so as to read photometric quantities directly. See visual photometer. 

pilot house control a mechanical means for controlling the elevation and train of a searchlight from a position on the other side of the bulkhead or deck on which it is mounted. 

point-by-point method† a method of lighting calculation, now called the point method. 

point method a lighting design procedure for predetermining the illuminance at various locations in

point source a source of radiation whose dimensions are sufficiently small, compared with the distance between the source and the irradiated surface, that these dimensions can be neglected in calculations and measurements. 

point vision the mode of vision of a small source of light such that the sensation is determined by its intensity rather than by its size. Point vision occurs with sources so small that their form or shape is not perceived and that they appear as points of light; this generally means less than 1-minute angular subtense.

pole (roadway lighting) a standard support generally used where overhead lighting distribution circuits are employed. 

portable lighting lighting involving equipment designed for manual portability. 

portable luminaire a lighting unit that is not permanently fixed in place. See table lamp and floor lamp. 

preheat (switch start) fluorescent lamp a fluorescent lamp designed for operation in a circuit requiring a manual or automatic starting switch to preheat the electrodes in order to start the arc. 

projector a lighting unit that, by means of mirrors and lenses, concentrates the light to a limited solid angle so as to obtain a high value of luminous intensity. See floodlight, searchlight, and signaling light. 

Glossary - O


O 

object color† the color of the light reflected or transmitted by an object when illuminated by a standard light source, such as CIE source A, B, C, or D65. See standard source and perceived object color.  

occulting light a rhythmic light in which the periods of light are clearly longer than the periods of darkness. 

opaque† impenetrable to light; not able to transmit, or not transmitting light. 

orientation the relation of a building with respect to compass directions. 

overcast sky one that has 100% cloud cover; the sun is not visible. 
overhang the distance between a vertical line passing through a specified point (often the photometric center) of a luminaire and the curb or edge of a roadway.

Glossary - N


N 

narrow-angle diffusion that in which flux is scattered at angles near the direction that the flux would take by regular reflection or transmission. See wide-angle diffusion. 

narrow-angle luminaire a luminaire that concentrates the light within a cone of a comparatively small solid angle. See wide-angle luminaire. 

normal lighting† permanently installed task and corridor electric lighting normally for use when the premises are occupied.