Search This Blog
Saturday, May 25, 2019
Facade lighting scheme
Dear Reader,
This is one of my façade lighting project. The building is an IT office with edgy design thus the feature can be highlighted by simply highlighting the edges.
Waiting for the project to be get completed. Will share the pics when its completed :) .
Sunday, January 27, 2019
What is Color Rendering Index (CRI)?
Color Rendering Index (CRI)
Lets break it down first
Color : We all know what that 'color' means.
Rendering : "process (an outline image) using colour and shading in order to make it appear solid and three-dimensional" - Google definition.
Index : "a sign or measure of something" - Google definition.
In lighting linguistics, CRI translates as the ability of the light source to bring out the colours of the object when the light falls on it. This parameter is measured in reference to rendering of the colors under the effect of the natural lights or under the sunlight.
Interpretation of CRI values:
CRI 90 - The colors will be as good as 90% when placed under sunlight. - (good)
CRI 85 - The colors will be as good as 85% when placed under sunlight. - (average)
CRI 70 - The colors will be as good as 70% when placed under sunlight. - (poor)
The higher the CRI, the better.
CRI is a crucial when it comes to indoor lighting. It really enhances the overall appearance of area or that particular painting which you want to stand out or that expensive carpet on the floor or that table meant for banquets.
An easy experiment to understand the difference:
Just open the palm of your hand on a broad daylight and pay attention to the blood vessels and the veins. Repeat the same under artificial light of CRI 90 then gradually down to CRI 70. One can see how these minute colors of blood vessel and veins become less & less prominent to the point one really has to look t it with more attention to see the difference.
So if there is an expensive painting say for example 'Mona Lisa' , with lots of different shades of all the colors known to "man" kind, will certainly look flat and bland. The missing colour details would strip the artwork of its magic and charm.
Therefore higher the CRI the better. Select the lamps with higher CRI for important indoor area or for a particular task of highlighting / focussing.
Sunday, December 30, 2018
Back lighting - Coves
Dear Reader,
In this blog we talk about the placement/positioning of the of the light source. Its important to conduct a mock up. Mock up is like a rehearsal before one takes up full scale installation. Its important to note the following:
1) Depth of the niche / cavity - this gives the idea on how to place the light source and the angle.
2) Texture or the type of surfaces - to know how likely one can see the hotspots / dots on the surface.
Below picture shows the positioning of the profiles / channels on which the led strips (in this case) is to be angled for the best results. However its important to note depending on the surface and the visual impact the decision has to be taken. Sometimes the brightness is the concern, the distance to which the light travels and sometimes just a faint glow is the intent. It all depends on how the finished project is going to look like.
In this blog we talk about the placement/positioning of the of the light source. Its important to conduct a mock up. Mock up is like a rehearsal before one takes up full scale installation. Its important to note the following:
1) Depth of the niche / cavity - this gives the idea on how to place the light source and the angle.
2) Texture or the type of surfaces - to know how likely one can see the hotspots / dots on the surface.
Below picture shows the positioning of the profiles / channels on which the led strips (in this case) is to be angled for the best results. However its important to note depending on the surface and the visual impact the decision has to be taken. Sometimes the brightness is the concern, the distance to which the light travels and sometimes just a faint glow is the intent. It all depends on how the finished project is going to look like.
Its always important to make sure that the surface is smooth so that the undulations of the surface do not impact the appearance of the finished project. In my next blog I'll try to explain the how to obtain the best results from the flexible strip lights.
Saturday, December 29, 2018
Monday, November 12, 2018
Sunday, November 11, 2018
Back lighting
Dear Reader,
Todays topic is about back lighting through perforated sheets. I would be using images from google, which best describe the intended techniques.There are several ways to back light a panel but some of the methods commonly chosen for a residential, hotel or indoor applications, are as follows:
Lets focus on the perforated sheet, probably made of metal sheet or an MDF. Notice the bright inner edges. Its because the light source has been installed on the inner side of the assembly and placed on the perimeter. Such arrangements are often customised according to the design or available spaces. So the technique may also vary.
In this case a flexible-cuttable-linear lighting fixture has been chosen, in other words LED Strips (<--google it). These strips are mounted via aluminum, channel flat or in angular shape. Angular shape is preferred but in some cases the light source gets visible which causes glare and kills the effect, so choose carefully.
The other methods could have been:
1) LED modules (google it): which offer wider range output and controls.
2) Linear rigid lighting: for higher outputs, They resemble batten lights.
3) RGB version of LED Strips.
2) Can go for RGB version. Pay attention to the application and purpose for which the area will be used.
3) LED strips should be installed on aluminum channels which makes the installation and lighitng effect to be in a straight line. It also helps in dissipating the heat from the led strips.
4) Special heat absorbing adhesive can be used for higher wattage led strips.
5) NO DOTS. Yes, dots should not be visible. Its a sudden death. Try to use diffusers or aim / place the source away from the visual field.
6) Don't go crazy with brightness. Brightness is not the answer, if the effect fails to improve the look and feel of the area then its all waste of money and time.
References of pictures used in this blog:
1)
https://www.google.com/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&cad=rja&uact=8&ved=2ahUKEwi2nPnRw8zeAhUN3Y8KHQFiBvQQjRx6BAgBEAU&url=https%3A%2F%2Fwww.indiamart.com%2Fproddetail%2Fdecorative-jali-4157134897.html&psig=AOvVaw3H7vtBSHhMFf8PZy0VZFLk&ust=1542031488199094
2)
https://i0.wp.com/img03.olx.in/images_olxin/302842995_1_1000x700_down-ceiling-designing-with-lighting-mdf-cutting-amritsar.jpg?resize=480%2C360&ssl=1
Todays topic is about back lighting through perforated sheets. I would be using images from google, which best describe the intended techniques.There are several ways to back light a panel but some of the methods commonly chosen for a residential, hotel or indoor applications, are as follows:
Case 1
Lets focus on the perforated sheet, probably made of metal sheet or an MDF. Notice the bright inner edges. Its because the light source has been installed on the inner side of the assembly and placed on the perimeter. Such arrangements are often customised according to the design or available spaces. So the technique may also vary.In this case a flexible-cuttable-linear lighting fixture has been chosen, in other words LED Strips (<--google it). These strips are mounted via aluminum, channel flat or in angular shape. Angular shape is preferred but in some cases the light source gets visible which causes glare and kills the effect, so choose carefully.
The other methods could have been:
1) LED modules (google it): which offer wider range output and controls.
2) Linear rigid lighting: for higher outputs, They resemble batten lights.
3) RGB version of LED Strips.
Case 2
This is a case of backlighting on the ceiling. Yes of course LED Strips can be used here. One should really consider a Panel LED Modules(google). These can be considered for ceiling, wall and even floor mount applications. They are basically best known for their uniformity of light effect and the drama that they create. You will need an expert hands for the job here as they are a delicate piece of light source.Case 3
For outdoor application always use an IP protected lighting products (IP54 onwards). If the enclosure is housing the light source is an IP protected one then indoor products can also be installed, i.e. IP20 rated lighting products. Conditions of using an IP 20 lighting products for an outdoor application will be discussed separately. Please read about the IP ratings or Ingress protection ratings on wiki or google.Do's and Don't
1) Light source should and always be invisible from the general visual field.2) Can go for RGB version. Pay attention to the application and purpose for which the area will be used.
3) LED strips should be installed on aluminum channels which makes the installation and lighitng effect to be in a straight line. It also helps in dissipating the heat from the led strips.
4) Special heat absorbing adhesive can be used for higher wattage led strips.
5) NO DOTS. Yes, dots should not be visible. Its a sudden death. Try to use diffusers or aim / place the source away from the visual field.
6) Don't go crazy with brightness. Brightness is not the answer, if the effect fails to improve the look and feel of the area then its all waste of money and time.
References of pictures used in this blog:
1)
https://www.google.com/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&cad=rja&uact=8&ved=2ahUKEwi2nPnRw8zeAhUN3Y8KHQFiBvQQjRx6BAgBEAU&url=https%3A%2F%2Fwww.indiamart.com%2Fproddetail%2Fdecorative-jali-4157134897.html&psig=AOvVaw3H7vtBSHhMFf8PZy0VZFLk&ust=1542031488199094
2)
https://i0.wp.com/img03.olx.in/images_olxin/302842995_1_1000x700_down-ceiling-designing-with-lighting-mdf-cutting-amritsar.jpg?resize=480%2C360&ssl=1
Sunday, September 9, 2018
Glossary - Z
Z
zonal-cavity
inter reflectance method a procedure for calculating
coefficients of utilization, wall exitance coefficients, and ceiling cavity
exitance coefficients, taking into consideration the luminaire intensity
distribution, room size and shape (cavity ratio concepts), and room
reflectances. It is based on flux transfer theory.
zonal
constant a factor by which the mean intensity emitted by a source
of light in a given angular zone is multiplied to obtain the lumens in the
zone. See Chapter 2, Measurement of Light and Other Radiant Energy.
zonal
factor interreflection method a procedure used for calculating
coefficients of utilization, based on integral equations, that takes into
consideration the ultimate disposition of luminous flux from every 10° zone
from luminaires.
zonal
factor method a procedure for predetermining, from typical
luminaire photometric data in discrete angular zones, the proportion of
luminaire output that would be incident initially (without interreflections) on
the workplane, ceiling, walls, and floor of a room.
zonal
multipliers multipliers for the flux in each 10-degree
conical zone from 0° (nadir) to 90° (horizontal) from a luminaire, expressing
the fraction of that zonal flux that is directly incident on the floor of a
room cavity. These multipliers are a function of the room cavity ratio and are
used to determine the direct ratio.
Glossary - W
W
watt†
the unit of power (rate of doing work). In electrical calculations, one watt is
the power produced by a current of one ampere across a potential difference of
one volt. The symbol often used in equations is "P," although
"W" is also acceptable.
wavelength†
the distance between two successive points of a periodic wave, in the direction
of propagation, at which the oscillation has the same phase.
wide-angle
diffusion that in which flux is scattered at angles far from the
direction that it would take by regular reflection or transmission. See
narrow-angle diffusion.
wide-angle
luminaire a luminaire that concentrates the light within the cone
of a comparatively large solid angle. See narrow-angle luminaire.
workplane the plane on which a visual task is usually
done, and on which the illuminance is specified and measured. Unless otherwise
indicated, this is assumed to be a horizontal plane 0.76 m (30 in.) above the
floor. Glossary - V
V
vacuum
lamp
an incandescent lamp in which the filament operates in an evacuated bulb.
valance a
longitudinal shielding member mounted across the top of a window or along a
wall (and is usually parallel to the wall) to conceal light sources, giving
both upward and downward distributions.
valance
lighting comprising light sources shielded by a panel parallel to
the wall at the top of a window.
vapor-tight
luminaire a luminaire designed and approved for installation in damp or wet
locations. It also is described as enclosed and gasketed.
veiling
brightness a brightness superimposed on the retinal image that
reduces its contrast. It is this veiling effect produced by bright sources or
areas in the visual field that results in decreased visual performance and
visibility.
veiling
reflection regular reflections that are superimposed upon diffuse
reflections from an object that partially or totally obscure the details to be
seen by reducing the contrast. This sometimes is called reflected glare.
Another kind of veiling reflection occurs when one looks through a plate of
glass. A reflected image of a bright element or surface can be seen
superimposed on what is viewed through the glass plate.
visibility the
quality or state of being perceivable by the eye. In many outdoor applications,
visibility is defined in terms of the distance at which an object can be just
perceived by the eye. In indoor applications it usually is defined in terms of
the contrast or size of a standard test object, observed under standardized
viewing conditions, having the same threshold as the given object. See
visibility (meteorological).
vision†
See central (foveal) vision, mesopic vision, peripheral vision, photopic
vision, and scotopic vision.
visual
acuity a measure of the ability to distinguish fine details,
measured with a set of optotypes (test types for determining visual acuity) of
different sizes. Quantitatively, it is the reciprocal of the minimum angular
size in minutes of the critical detail of an object that can just be seen.
visual
angle the angle that an object or detail subtends at the point
of observation. It usually is measured in minutes of arc.
visual
comfort probability (VCP) the rating of a lighting system
expressed as a percent of people who, when viewing from a specified location
and in a specified direction, will be expected to find it acceptable in terms
of discomfort glare. Visual comfort probability is related to the discomfort
glare rating (DGR).
visual
field the locus of objects or points in space that can be
perceived when the head and eyes are kept fixed. Separate monocular fields for
the two eyes can be specified or the combination of the two. See binocular
portion of the visual field, central visual field, monocular visual field, and
peripheral visual field.
visual
perception the interpretation of impressions transmitted from the
retina to the brain in terms of information about a physical world displayed
before the eye. Note Visual perception
involves any one or more of the following recognizing the presence of something
(object, aperture, or medium); identifying it; locating it in space; noting its
relation to other things; and identifying its movement, color, brightness, or
form.
visual
performance the quantitative assessment of the
performance of a visual task, taking into consideration speed and
accuracy.
visual
range (of a light or object) the maximum distance at which
that particular light (or object) can be seen and identified.
visual
task
conventionally designates those details and objects that must be seen for the
performance of a given activity, and includes the immediate background of the
details or objects. Note The term visual
task as used is a misnomer because it refers to the visual display itself and
not the task of extracting information from it. The task of extracting
information also has to be differentiated from the overall task performed by
the observer.
volt† the difference in electrical potential between
two points in a circuit. It is also called the electromotive force. The symbol
often used in equations is "E" (from the latter term), although
"V" is also acceptable. Glossary - U
U
ultraviolet
lamp
a lamp that emits a significant portion of its radiative power in the
ultraviolet (UV) part of the spectrum; the visible radiation is not of
principal interest.
upward
component that portion of the luminous flux from a luminaire
emitted at angles above the horizontal. See downward component.
Glossary - T
T
table
lamp a portable luminaire with a short stand, suitable for
standing on furniture.
tail
lamp
a lighting device used to designate the rear of a vehicle by a warning
light.
task
ambient lighting a combination of task lighting and ambient
lighting within an area such that the general level of ambient lighting is
lower than and complementary to the task lighting.
task
lighting directed to a specific surface or area that provides
illumination for visual tasks.
thermopile† a
thermal radiation detector consisting of a number of thermocouples
interconnected in order to increase the sensitivity to incident radiant
flux.
torchère an
indirect floor lamp that sends all or nearly all of its light upward.
total
internal reflectance (TIR)† total reflection of a light ray at a
surface of a transmitting medium occurs when the angle of incidence exceeds a certain
value whose sine equals n2/n1, the ratio of indices of refraction, or when sin
r = 1, where r equals
transition
lighting in roadway lighting, lighting gauged to compensate for
visual adaptation between regions of high and low light level, as when entering
tunnels.
translucent†
transmitting light diffusely or imperfectly.
transparent†
having the property of transmitting rays of light through its substance so that
bodies situated beyond or behind can be distinctly seen (opposed to opaque and
usually distinguished from translucent).
troffer a long recessed lighting unit usually installed
with the opening flush with the ceiling. The term is derived from
"trough" and "coffer"Glossary - S
S
scoop a
floodlight consisting of a lamp in an ellipsoidal or paraboloidal matte
reflector, usually in a fixed relationship, though some types permit adjustment
of the beam shape.
scotopic
vision mediated essentially or exclusively by the rods. It is
generally associated with adaptation to a luminance below about 0.034 cd/m2.
See photopic vision.
self-ballasted
lamps any arc discharge lamp of which the current-limiting
device is an integral part.
semi-direct
lighting involving luminaires that distribute 60 to 90% of the
emitted light downward and the balance upward.
semi-indirect
lighting involving luminaires that distribute 60 to 90% of the
emitted light upward and the balance downward.
service
period the number of hours per day for which daylighting
provides a specified illuminance level. It often is stated as a monthly
average.
set
light in theatrical lighting, the separate illumination of
background or scenic elements.
shade a
screen made of opaque or diffusing material that is designed to prevent a light
source from being directly visible at normal angles of view.
shielding
angle (of a luminaire) the angle between a horizontal line
through the light center and the line of sight at which the bare source first
becomes visible. See cutoff angle (of a luminaire).
side
light lighting from the side to enhance subject modeling and
place the subject in depth, apparently separated from the background.
signal
shutter a device that modulates a beam of light by mechanical
means for the purpose of transmitting intelligence.
sky
factor the ratio of the illuminance on a horizontal plane at a
given point inside a building due to the light received directly from the sky,
to the illuminance due to an unobstructed hemisphere of sky of uniform
luminance equal to that of the visible sky.
sky
light† visible radiation from the sun redirected by the
atmosphere.
soft
light (1) diffuse illumination that produces soft-edged,
poorly defined shadows on the background when an object is placed in its path;
(2) a luminaire designed to produce such illumination.
solar
efficacy the ratio of the solar illuminance constant to the solar
irradiance constant. The current accepted value is 94.2 lm/W.
spacing-to-mounting-height
ratio, S/MHwp† the ratio of the actual distance
between luminaire centers to the mounting height above the workplane. Also, an
obsolete term that described a characteristic of interior luminaires. See
luminaire spacing criterion.
special
color rendering index, Ri measure of color shift of various
standardized special colors, including saturated colors, typical foliage, and
Caucasian skin. It also can be defined for other color samples when the
spectral reflectance distributions are known.
specular
surface one from which the reflection is predominantly regular.
See regular (specular) reflection.
speed
of light† the speed of all radiant energy, including light, is
2.9979258 × 108 m/s in vacuum (approximately 186,000 mi/s). In all
material media the speed is less and varies with the material's index of
refraction, which itself varies with wavelength.
sphere
illumination illumination on a task from a source
providing equal luminance in all directions about that task, such as an
illuminated sphere with the task located at the center.
spotlight any
of several different types of luminaires with narrow beam angle designed to
illuminate a well-defined area. In motion pictures, generic for Fresnel lens
luminaires. Also, a form of floodlight, usually equipped with lenses and
reflectors to give a fixed or adjustable narrow beam.
standard
source an electric light source having the same spectral power
distribution as a specified standard illuminant.
starter a
device used in conjunction with a ballast for the purpose of starting an
electric-discharge lamp.
state
of chromatic adaptation the condition of the chromatic
properties of the visual system at a specified moment as a result of exposure
to the totality of colors of the visual field currently and in the past.
stray
light (in the eye) light from a source that is scattered onto
parts of the retina lying outside the retinal image of the source.
street
lighting luminaire a complete lighting device consisting of a
light source and ballast, where appropriate, together with its direct
appurtenances such as globe, reflector, refractor, housing, and such support as
is integral with the housing. The pole, post, or bracket is not considered part
of the luminaire. Note Modern street
lighting luminaires contain the ballasts for high-intensity discharge lamps
where such lamps are used; a photocontrol can be mounted on the luminaire.
street
lighting unit the assembly of a pole or lamp post with a
bracket and a luminaire.
striplight
(theatrical) once an open trough reflector containing a series of lamps; now
usually a compartmentalized luminaire with each compartment containing a lamp,
reflector, and color frame holder, wired in rotation in three or four circuits
and used as borderlights, footlights, or cyclorama lighting from above or
below. Often in short 0.9- to 2.4-m [3- to 8-ft] portable sections.
stroboscopic
lamp
(strobe light) a flash tube designed for repetitive flashing.
supplementary
lighting used to provide an additional quantity and quality of
illumination that cannot readily be obtained by a general lighting system and
that supplements the general lighting level, usually for specific work
requirements.
surface-mounted
luminaire a luminaire that is mounted directly on a ceiling.
suspended
(pendant) luminaire a luminaire that is hung from a ceiling by supports.
Systeme Internationale (SI)† a measurement system used
throughout the world, commonly referred to as the metric system. Public Law
100-418 designated the metric system as the preferred system of weights and
measures for the United States. Glossary - R
R
radiant
energy, Q energy traveling in the form of electromagnetic
waves. It is measured in units of energy such as joules or kilowatt hours. See
spectral radiant energy.
radiometry the
measurement of quantities associated with radiant energy and power.
rated
lamp
life the life value assigned to a particular type lamp. This is commonly a
statistically determined estimate of average or of median operational life. For
certain lamp types other criteria than failure to light can be used; for
example, the life can be based on the average time until the lamp type produces
a given fraction of initial luminous flux.
reflectance of
a surface or medium, ρ = Φr/Φi the ratio of the reflected flux to the incident
flux. Reflectance is a function of:
1. Geometry
a. of the incident flux b. of collection for the reflected flux
2. Spectral distribution
a. characteristic of the
incident flux b. weighting function for
the collected flux
3. Polarization
a. of the incident flux b. component defined for the collected
flux.
reflectance
factor, R the ratio of the flux actually reflected by a sample
surface to that which would be reflected into the same reflected-beam geometry
by an ideal (glossless), perfectly diffuse (lambertian), completely reflecting
standard surface irradiated in exactly the same way as the sample. Note the
analogies to reflectance in the fact that nine canonical forms are possible
that "spectral" can be applied as a modifier, that it can be luminous
or radiant reflectance factor, and so on. Note that reflectance cannot exceed
unity, but reflectance factor can have any value from zero to values
approaching infinity.
reflected
glare glare resulting from reflections of high luminances in
polished or glossy surfaces in the field of view. It usually is associated with
reflections from within a visual task or areas in close proximity to the region
being viewed. See veiling reflection.
reflection a
general term for the process by which the incident flux leaves a (stationary)
surface or medium from the incident side without change in frequency. Note Reflection is usually a combination of
regular and diffuse reflection. See regular (specular) reflection, diffuse
reflection, and veiling reflection.
reflectivity†
reflectance of a layer of a material of such a thickness that there is no
change of reflectance with increase in thickness.
reflectometer a
photometer for measuring reflectance.
Note Reflectometers can be visual or physical instruments.
reflector a
device used to redirect the flux from a source by the process of reflection.
See retro-reflector.
refraction†
the process by which the direction of a ray of light changes as it passes
obliquely from one medium to another in which its speed is different.
refractor a
device used to redirect the flux from a source, primarily by the process of
refraction.
retina a
membrane lining the posterior part of the inside of the eye. It comprises
photoreceptors (cones and rods) that are sensitive to light and nerve cells
that transmit to the optic nerve the responses of the receptor elements.
rhythmic
light a light that when observed from a fixed point has a luminous intensity
that changes periodically. See equal interval (isophase) light, flashing light,
group flashing light, interrupted quickflashing light, and occulting
light.
room
cavity the cavity formed by the plane of the luminaires, the work
plane, and the wall surfaces between these two planes.
room
cavity ratio (RCR) a number indicating room cavity proportions,
calculated from the length, width, and height. See zonal-cavity
interreflectance method.
room
utilization factor (utilance) the ratio of the luminous flux
(lumens) received on the workplane to that emitted by the luminaire. Note This
ratio sometimes is called interflectance. Room utilization factor is based on
the flux emitted by a complete luminaire, whereas coefficient of utilization is
based on the total flux generated by the lamps in a luminaire.
room surface dirt depreciation (RSDD) the fractional loss of
task illuminance due to dirt on the room surfaces. Glossary - Q
Q
quality
of lighting pertains to the distribution of luminance in
a visual environment. The term is used in a positive sense and implies that all
luminances contribute favorably to visual performance, visual comfort, ease of
seeing, safety, and aesthetics for the specific visual tasks involved.
Glossary - P
P
panel
(open) face exit sign† a transilluminated sign where both the exit legend and
background are translucent.
parking
lamp
a lighting device placed on a vehicle to indicate its presence when
parked.
partial
diffusion† See incomplete diffusion.
partly
cloudy sky a sky that has 30 to 70% cloud cover.
passing
beams† See lower (passing) beams.
pendant
luminaire† See suspended (pendant) luminaire.
perceived
light source color the color perceived to belong to a light
source.
perceived
object color† the color perceived to belong to an object
resulting from characteristics of the object, of the incident light, and of the
surround, the viewing direction, and observer adaptation. See object
color.
percent
flicker a relative measure of the cyclic variation in output of
a light source (percent modulation). It is given by the expression where A is
the maximum and B is the minimum output during a single cycle. See Chapter 6,
Light Sources.
perfect
diffusion that in which flux is uniformly scattered in accord with
Lambert's cosine law.
peripheral
vision the seeing of objects displaced from the primary line of
sight and outside the central visual field.
peripheral
visual field that portion of the visual field that falls
outside the region corresponding to the foveal portion of the retina.
phosphor
mercury lamp† see mercury-fluorescent lamp.
phosphorescence the
emission of light as the result of the absorption of radiation, and continuing
for a noticeable length of time after excitation (longer than approximately
10−8 s).
phot, ph
a unit of illuminance equal to one lumen per square centimeter. The use of this
unit is deprecated.
photobiology a
branch of biology that deals with the effects of optical radiation on living
systems.
photometer an
instrument for measuring photometric quantities such as luminance, luminous
intensity, luminous flux, or illuminance. See densitomer, goniophotometer,
illuminance (lux or footcandle) meter, integrating photometer, reflectometer,
spectrophotometer, and transmissometer.
photometry the
measurement of quantities associated with light. Note Photometry can be either visual, in
which the eye is used to make a comparison, or physical, in which measurements
are made by means of physical receptors.
phototherapy the
treatment of disease involving the use of optical radiation.
physical photometer an
instrument containing a physical receptor and associated filters that is
calibrated so as to read photometric quantities directly. See visual
photometer.
pilot
house control a mechanical means for controlling the
elevation and train of a searchlight from a position on the other side of the
bulkhead or deck on which it is mounted.
point-by-point
method† a method of lighting calculation, now called the point
method.
point method a lighting
design procedure for predetermining the illuminance at various locations in
point
source a source of radiation whose dimensions are sufficiently
small, compared with the distance between the source and the irradiated surface,
that these dimensions can be neglected in calculations and measurements.
point
vision the mode of vision of a small source of light such that
the sensation is determined by its intensity rather than by its size. Point
vision occurs with sources so small that their form or shape is not perceived
and that they appear as points of light; this generally means less than
1-minute angular subtense.
pole (roadway lighting) a
standard support generally used where overhead lighting distribution circuits
are employed.
portable lighting lighting
involving equipment designed for manual portability.
portable luminaire a
lighting unit that is not permanently fixed in place. See table lamp and floor
lamp.
preheat
(switch start) fluorescent lamp a fluorescent lamp designed for operation in a
circuit requiring a manual or automatic starting switch to preheat the
electrodes in order to start the arc.
projector a
lighting unit that, by means of mirrors and lenses, concentrates the light to a
limited solid angle so as to obtain a high value of luminous intensity. See
floodlight, searchlight, and signaling light.
Glossary - O
O
object
color† the color of the light reflected or transmitted by an
object when illuminated by a standard light source, such as CIE source A, B, C,
or D65. See standard source and perceived object color.
occulting
light a rhythmic light in which the periods of light are
clearly longer than the periods of darkness.
opaque†
impenetrable to light; not able to transmit, or not transmitting light.
orientation the relation of
a building with respect to compass directions.
overcast
sky one that has 100% cloud cover; the sun is not visible.
overhang the distance between a vertical line passing
through a specified point (often the photometric center) of a luminaire and the
curb or edge of a roadway.Glossary - N
N
narrow-angle
diffusion that in which flux is scattered at angles near the
direction that the flux would take by regular reflection or transmission. See
wide-angle diffusion.
narrow-angle
luminaire a luminaire that concentrates the light within a cone of
a comparatively small solid angle. See wide-angle luminaire.
normal
lighting† permanently installed task and corridor electric
lighting normally for use when the premises are occupied.
Subscribe to: